Traction Air Insulated DC Switchgears

Traction Air Insulated DC Switchgears
TAIS 0.6-3.3 kV IS&T series

TAIS DC IS&T air insulated switchgear is:

  • A prefabricated metal structure consisting of a galvanized steel body with metal partitions between compartments;
  • Indoor installation;
  • Single-sided maintenance (two-sided upon request);
  • With fast 1-pole DC air circuit breakers;
  • With DC current 1-pole/2-poles disconnectors.
TAIS DC IS&T replaces the following well-known analogs:

TAIS DC IS&T has the following applications:

  • Power supply of the contact network of direct current for light rail system (600V)
  • Power supply of the contact network of direct current for Tram system (600V)
  • Power supply of the contact network of direct current for Trolley bus system (600V)
  •  Power supply of the contact network of direct current for Urban metro (750V, 825V, 1500V)
  •  Power supply of the contact network of direct current for Railways (3000V, 3300V)

TAIS DC IS&T consisting of:

  • Medium voltage DC switchgears and connecting devices;
  • Shunt for current measuring;
  • Voltage sensors;
  • Air 1-pole circuit breakers;
  • DC current 1-pole/2-poles disconnectors;
  • Auxiliary devices (surge arresters, earthing disconnectors);
  • Protection, monitoring and control units for each cabinet:
  • Protection relays and automation devices;
  • Predictive systems (contacts temperature control, acoustic sensors for partial discharge, etc.)
  • Systems designed according to the Customer's technical specifications.
  • For the substation as a whole:
  • Auxiliary needs systems (APS/PSN) and operational current (DC current panels);
  • Relay protection and automation systems;
  • Automation, telemechanics and telemetry panels and boards;
  • Counter panels and boards;
  • Communication panels;
  • Dispatcher's workstation;
  • Intersystem communications.

TAIS DC IS&T for digital substations and SmartGrid systems:

  • Integration of all secondary devices using a single IEC-61850 protocol;
  • Use of a single connection controller with automation, telemechanics and telemetry. Protection relay, monitoring devices, Feeder fault sensor, digital sensors - are connected to the control panel;
  • Acoustic partial discharge sensors and cable joint condition monitoring system;
  • Digital current sensors;
  • Digital voltage sensors;
  • Innovative Feeder Fault Detection system.
TAIS IS&T technical parameters
* For positive busbar switchgears - Cathode, Feeder, Spare switch switchgears.
** For negative busbar switchgears - Anode, Linear, Grounding disconnector switchgears.