Dry Air Insulated Switchgears

Dry Air Insulated Switchgears
DAIS 7.2-12 kV IS&T

DAIS 7,2-12 kV IS&T is:

  • A prefabricated metal structure consisting of a galvanized steel body with metal partitions between the compartments;
  • With a stainless steel gas-insulated tank;
  • Indoor installation;
  • Front-sided maintenance;
  • With vacuum circuit breakers,
  • With load break switches.
DAIS 7,2-12 kV IS&T replaces the following well-known analogs:

DAIS 7.2-12 kV IS&T has the following applications:

  • City and municipal networks;
  • The system of own needs and power output of power plants;
  • Distribution networks of the energy complex;
  • Oil, coal and gas industries;
  • Substations of industrial enterprises.

DAIS 7.2-12 kV IS&T consisting of:

  • High-voltage switchgears and connecting devices;
  • Current and voltage transformers;
  • Vacuum circuit breakers in Clean Dry Air insulation;
  • Load break switches in Clean Dry Air insulation;
  • Auxiliary devices (cable adapters, main busbar adapters, surge arresters);
  • Protection, monitoring and control units for each cabinet:
  • Protection relays and automation devices;
  • Predictive systems (contacts temperature control, acoustic sensors for partial discharge, etc.)
  • Systems designed according to the Customer's technical specifications.
  • For the substation as a whole:
  • Auxiliary needs systems (APS/PSN) and operational current (DC current panels);
  • Relay protection and automation systems;
  • Automation, telemechanics and telemetry panels and boards;
  • Counter panels and boards;
  • Communication panels;
  • Dispatcher's workstation;
  • Intersystem communications.

DAIS 7.2-12 kV IS&T for digital substations and SmartGrid systems:

  • Integration of all secondary devices using a single IEC-61850 protocol;
  • Use of a single connection controller with automation, telemechanics and telemetry. Protection relay, monitoring devices, Feeder fault sensor, digital sensors - are connected to the control panel;
  • Acoustic partial discharge sensors and cable joint condition monitoring system;
  • Digital current sensors;
  • Digital voltage sensors;
  • Innovative Feeder Fault Detection system.
DAIS 7.2-12 kV IS&T technical parameters:
* Width is calculated as:
--- For monoblock: the sum of the widths of all functions, and 23 mm for left and right sides.
Example: standard monoblock CVC for 12 kV is 3x400+2x23=1246 mm
--- For separate switchgear box: width of function, and 23 mm for left and right sides.
Example: standard separate switchgear box V for 12 kV is 400+2x23=446 mm
** Height for switchgear box with relay compartment (D-part).